FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v3 Release Notes Version Number B.11.31.1303 HP Part Number: 5900-3006 Published: March 2013 Edition: 1.
Contents FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v3 overview..............................3 New and changed features in this release...................................................................................3 New features......................................................................................................................3 Changed features................................................................................................................
This document provides information about the B.11.31.1303 release of the FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v3. FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v3 overview This release of the document for the FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v3 (version B.11.31.1303) documents version changes and defect fixes. New and changed features in this release New features There are no new features in this release.
Table 3 HP-UX September 2012 (AR1209) Fixes Defect ID Description QXCR1001215918 The fcd driver is now bundled with new Q-Logic firmware version 5.06.05, supported for 4Gb and 8Gb Q-Logic FC HBAs. The firmware release note can be found at http:// filedownloads.qlogic.com/files/driver/82446/release.pdf.
Table 9 HP-UX March 2011 (AR1103) Fixes Defect ID Description QXCR1001020559 SNIA: FC Instance Enumeration FCPortControllerCollection fails if port disabled. QXCR1001073517 SNIA: FC Provider dumps core during CHO test. QXCR1001051386 This fixes the issue where the fcd driver does not restore the Symbolic Names to their default values when requested through scsimgr. QXCR1001041080 This fixes a memory leak in the fcd driver after executing certain fcmsutil echo, test, and rls commands.
Table 12 HP-UX March 2010 (WEB1003) Fixes Defect ID Description QXCR1000887704 This fixes an issue where the SNIA returns HBA_STATUS_ERROR for HBA_SendCTPassThru API call failure. QXCR1001007011 This fixes a Serviceguard “safety timer” panic on a single-cpu vpar configuration, when the command fcmsutil_ns_query_port is executed. QXCR1000994941 This fixes the issue in the fcd driver that can intermittently result in a mailbox timeout fatal error.
Table 17 HP-UX September 2008 Fixes Defect ID N/A Description There are no fixes for the September 2008 release. Table 18 HP-UX March 2008 Fixes Defect ID Description QXCR1000754446 Added Symbolic Name support. Symbolic Names are user friendly names assigned to SAN components, and registered with the name server of an FC switch. FC switches display the registered symbolic names, which can be used by users to correlate SAN components across multiple servers and storage.
Executing this command will create the necessary device special files which the FCD OL* script did not create during the execution of olrad -A. • Private Loop and Public Loop topology configuration support for Fibre Channel mezzanine adapters Private Loop and Public Loop topology configurations are not supported for Fibre Channel mezzanine adapters on HP Integrity Blade servers in combination with the Fibre Channel (FC) Pass Thru I/O Interconnect modules.
6. 7. 8. 9. 10. Press 7 to select the Connection Option. Press 3 to select Loop Preferred, Otherwise Point to Point option. Press 0 to go back to the previous menu. Under Main Menu, press 11 to write the changes to the NVRAM. Also under Main Menu, press 12 to quit and go back to the EFI shell. NOTE: The HP-UX 11iv3 AR1203 FibrChanl-01 (fcd) driver will display a warning message on detecting loop topology for HP 8Gb and 4Gb Dual Port Qlogic Mezzanine HBAs (part numbers 451871–B21 and 403619–B21).
Corrective action: Retry the operation at a time when the system has more free memory available. • DLKM infrastructure must be installed A complete Dyamically Loadable Kernel Module (DLKM) infrastructure is required for FibrChanl-01 B.11.31.0803.
HBAs are: A6826A, A9782A, A9784A, and AB465A with EFI driver version 1.47 or earlier. Affected 4Gb Fibre Channel HBAs are: AB378A and AB379A with EFI driver version 1.01. The boot will fail with a message similar to the following: Load of HP-UX Primary Boot: 1.0.1/1/0/4/0.8.0.255.0.6.0 failed: Not Found Corrective action: A fix in the 2Gb/4Gb drivers has been released. The following steps will resolve the issue: 1. Go to www.hp.com 2. Click Software & Driver Downloads. 3.
Operating system and version compatibility The following software (or later versions) must be installed before installing the FibrChanl-01 (fcd) driver, version B.11.31.1303 into a system: • PHCO_36371 (PCI OL* DLKM and Chassis Delete) • PHKL_36332 (Cumulative GIO Patch) • PHKL_36387 (MCA Recovery/Shutdown Patch) • PHCO_36356 (Mass Storage Critical Resource Analysis) • PHCO_36530 (Software Distributor Patch) • HP-UX CommonIO 11.31 (B.11.31.0709 or later). NOTE: The FC-COMMON.
For current recommended firmware versions, see the HP-UX Fibre Channel (fcd and fclp) Host Bus Adapter Support Matrix at http://www.hp.com/go/hpux-iocards-docs . NOTE: vpd Display EFI driver and ROM firmware versions using fcmsutil EFI/firmware bundles can be downloaded from www.hp.com, in the Software and Driver Downloads section. Driver versions The following table lists all the driver versions of the fcd driver on HP-UX 11i v3 with their associated release names and dates.
• AD300A PCIe Dual Port 4Gb Fibre Channel Adapter • AB378B PCI-X Single Port 4Gb Fibre Channel Adapter • AB379B PCI-X Dual Port 4Gb Fibre Channel Adapter • AB378A PCI-X Single Port 4Gb Fibre Channel Adapter • AB379A PCI-X Dual Port 4Gb Fibre Channel Adapter • AB6826A PCI-X Dual Port 2 Gb/1 Gb Fibre Channel Adapter • A9782A PCI-X 2Gb Fibre Channel and 1000Base-SX (Fiber) Gigabit Ethernet Combination Card • A9784A PCI-X 2Gb Fibre Channel and 1000Base-T (Copper) Gigabit Ethernet Combination Card