FibrChanl-01 (fcd) B.11.31.1311 Fibre Channel Mass Storage Driver for HP-UX 11i v3 Release Notes

This document provides information about the B.11.31.1311 release of the FibrChanl-01 (fcd)
Fibre Channel Mass Storage Driver for HP-UX 11i v3.
FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v3
overview
This release of the document for the FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for
HP-UX 11i v3 (version B.11.31.1311) documents version changes and defect fixes.
New and changed features in this release
New features
The following feature is new with the B.11.31.1311 version of the FibrChanl-01 (fcd) Fibre Channel
Mass Storage Driver for HP-UX 11iv3:
This version of the FibrChanl-01 (FCD) driver delivers a new set of the SNIA library required
by Veritas Volume Manager (VXVM) product versions 5.0.1 and 5.1SP1 or later. For additional
details please refer to HP CommonIO B.11.31.1311 Release Notes for HP-UX 11i v3 at
www.hp.com/go/common-io-docs.
NOTE: There is no change to the existing SNIA library delivered as part of this FibrChanl-01
product.
Changed features
There are no changed features in this release.
Known problems fixed in this version
The following issues have been fixed in the FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver
for HP-UX 11i v3 November 2013 (WEB1311) release. To view the entire details of each issue
fix, refer to the HP IT Resource Center at: http://forums1.itrc.hp.com/service/forums/home.do
Table 1 HP-UX November 2013 (WEB1311) Fixes
DescriptionDefect ID
This fixes an issue faced after disabling and enabling uplink port where ioscan output shows
lunpath state as NO_HW for luns connected to the VFC (virtual Fibre Channel controller) port.
QXCR1001292193
Table 2 HP-UX September 2013 (WEB1309) Fixes
DescriptionDefect ID
This fixes an IO hang issue that happens after interrupt migration failure.QXCR1001278746
This fixes a link failover issue in QLogic 8Gb Firmware for the 8Gb Mezzanine Fibre Channel
adapter attached to HP VC 24P module. The fcd driver is now bundled with new QLogic firmware
version 5.06.06.
QXCR1001297902
Table 3 HP-UX March 2013 (AR1303) Fixes
DescriptionDefect ID
This is fix for an issue where fcd HBA shows abnormally large value for avque field of "sar -H"
command output when there is no IO.
QXCR1001255911
FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v3 overview 3