FibrChanl-02 (fclp) B.11.23.1009 Fibre Channel Mass Storage Driver for HP-UX 11i v2 Release Notes

This document provides information about the B.11.23.1009 release of the FibrChanl-02 (fclp)
Fibre Channel Mass Storage Driver for HP-UX 11i v2.
FibrChanl-02 (fclp) Fibre Channel Mass Storage Driver for HP-UX 11i v2
overview
This release of the document for the FibrChanl-02 (fclp) Fibre Channel Mass Storage Driver for
HP-UX 11i v2 (version B.11.23.1009) documents defect fixes and version changes.
New and changed features in this release
New features
The following feature is new with the B.11.23.1009 version of the FibrChanl-02 (fclp) Fibre Channel
Mass Storage Driver for HP-UX 11i v2:
There are no new features with this release.
Known problems fixed in this version
The following issue has been fixed in the FibrChanl-02 (fclp) Fibre Channel Mass Storage Driver
for HP-UX 11i v2 September 2010 (AR1009) release. To view the entire details of each issue fix,
refer to the HP IT Resource Center at: http://forums1.itrc.hp.com/service/forums/home.do
Table 1 HP-UX September 2010 (AR1009) Fixes
DescriptionDefect ID
Certain new tape drives and tape libraries can generate previously unseen FC traffic, that
fclp does not handle properly, resulting in a panic with a data TLB fault. This problem
has been corrected.
QXCR1001004749
In an arbitrated loop configuration, some storage targets might remain offline if the HBA
temporarily loses and then regains its connection to the target (for example, via a cable
disconnect and reconnect). This problem has been corrected.
QXCR1000991122
Corrected a timing-related fclp driver issue that caused an inconsistent driver state; this
condition could result in a single I/O being completed twice.
QXCR1001006125
SNIA dumps core with command vxesd with fclp cards and driver.
QXCR1000876391
Table 2 HP-UX March 2010 (AR1003) Fixes
DescriptionDefect ID
There are no fixes for this release.N/A
Table 3 HP-UX September 2009 Fixes
DescriptionDefect ID
This fixes the issue where the fclp startup script removed the volume group directory in
/dev/fclp, followed by a number and vg name, such as /dev/fclp1dbvg03.
QXCR1000914949
Table 4 HP-UX March 2009 Fixes
DescriptionDefect ID
There are no fixes for the 0903 release.N/A
FibrChanl-02 (fclp) Fibre Channel Mass Storage Driver for HP-UX 11i v2 overview 5