FibrChanl-02 (fclp) B.11.31.0906 Fibre Channel Mass Storage Driver Release Notes, Edition 3.0 (June 2009)

It is not possible to update previous recipes/versions of the Mezzanine card to be compatible
with the HP Integrity blades.
Identification
The following are the ways to identify the versions of the cards that are compatible with Integrity
c-Class blades.
EDC Change
The newer cards are built with an Engineering Date Code that marks the changes required for
Integrity Integrity-supported versions have an EDC of B-4813 or later.
The EDC code is printed on a label on the box containing the card, on a label on the card, and is
included in the Vital Products Data (VPD) that is flashed into the card during the manufacture
of the part. This means that you will be able to identify a version of the card supported on Integrity
both visually and electronically.
On HP-UX, the fcmsutil /dev/fclpX vpd command displays the VPD:
# fcmsutil /dev/fclp5 vpd
V I T A L P R O D U C T D A T A
--------- ------------- -------
Product Description : "HP BLc Emulex LPe1105-HP FC Mezz Option Kit"
Part number : "404987-001"
10