FibrChanl-02 (fclp) B.11.31.1009 Fibre Channel Mass Storage Driver for HP-UX 11i v3 Release
NOTE: AR0803 was the initial release of FibrChanl-02 (fclp) on HP-UX 11i v3.
Known problems and limitations
This section provides a list of known problems and limitations as known to HP at time of
publication. If workarounds are available, they are included.
• A voltage degradation alert message is shown in the System Events Logs upon system
boot up
This is only an alert message for the 456972-B21 HBA. Functionality and performance on
the Mezzanine card are not adversely affected. No actions are needed. This message can
only be found through the SL command under the MP menu.
• EFI is only bootable from the first boot entry device
This applies to the first boot entry device that is connected to an AD221, AD222A, AD393A,
AD299A, or AD355A.
Corrective action: The workaround for this issue is to re-arrange the boot list that is connected
to the adapters:
1. Select Boot Options Maintenance Menu from the EFI Boot Manager's main menu.
2. Use the following three Boot Options Maintenance Menu items to edit the boot
options list, so that the fibre device connected to an AD221A, AD222A, AD393A,
AD299A, or AD355A is listed as the first entry in the boot options list:
— Add A Boot Option: presents you with a list of possible boot devices, and
allows you to select one to add to your boot options list.
— Delete Boot Option(s): allows you to interactively delete one or more entries
from your boot options list.
— Change Boot Order: allows you to re-order your boot options list.
3. When the boot options list for your system has been re-ordered as you wish, select Exit
to return to the EFI Boot Manager's main menu, which should now reflect your edits
to the boot options list.
• EFI boot fails with no HP-UX partition on boot media message
Loading.: HP-UX Primary Boot: 0/4/0/0/0/0.8.0.20.0.3.0
Starting: HP-UX Primary Boot: 0/4/0/0/0/0.8.0.20.0.3.0
Using EFI boot partition (no HPUX partition on boot media)
(C) Copyright 1999-2006 Hewlett-Packard Development Company, L.P.
All rights reserved
HP-UX Boot Loader for IPF -- Revision 2.029
Press Any Key to interrupt Autoboot
\EFI\HPUX\AUTO ==> boot vmunix
Seconds left till autoboot - 0
AUTOBOOTING...Could not open file vmunix to check for a directory
Could not open vmunix
loading failed
HPUX>
This issue is addressed in system firmware version 3.01 for rx2660, rx3600, and rx6600. There
are three workarounds for this issue:
Known problems and limitations 7