FibrChanl-02 (fclp) B.11.31.1103 Fibre Channel Mass Storage Driver for HP-UX 11i v3 Release Notes

NOTE: Display EFI driver and ROM firmware versions using fcmsutil <fclp_device_file>
vpd
EFI/firmware bundles can be downloaded from www.hp.com, in the Software and Driver Downloads
section.
Hardware Requirements
This version of the FibrChanl-02 (fclp) Fibre Channel Mass Storage Driver for HP-UX 11i v3 runs
on HP Integrity servers with the HP-UX 11i v3 (11.31) operating system. It supports Fibre Channel
hardware products such as:
AH403A PCIe Dual Port 8Gb Fibre Channel Adapter
AH402A PCIe Single Port 8Gb Fibre Channel Adapter
456972-B21 Dual Port PCIe Emulex 8 Gb Mezzanine Fibre Channel Adapter
AD355A PCIe Dual Port 4Gb Fibre Channel Adapter
AD299A PCIe Single Port 4Gb Fibre Channel Adapter
AD221A HP PCIe Single Port 4Gb Fibre Channel and Single Port 1000 BT Adapter
AD222A HP PCIe Dual Port 4Gb Fibre Channel and Dual Port 1000BT Adapter
AD393A HP PCIe Dual Port 4Gb Fibre Channel and Dual Port 1000SX Adapter
403621-B21 Emulex LPe1105–HP 4Gb Fibre Channel Adapter for HP c-Class BladeSystem
NOTE: Please note the following slot limitations on rx3600 and rx6600 servers:
Slots 5 and 6 are the recommended slots for AD221A, AD222A, and AD393A adapters.
Slots 3 and 4 are also supported for AD221A, AD222A, and AD393A adapters, but with
the following restrictions:
I/O performance of the card may be limited.
Online Replacement is not supported.
Emulex 4Gb Fibre Channel Mezzanine (403621-B21) on HP Integrity blade servers
The Emulex LPe1105-HP 4Gb Fibre Channel Mezzanine Card for HP c-Class BladeSystem (Product
Number 403621-B21) has been shipping on HP Proliant c-Class blades for some time. The cards
have been modified to be compatible with HP Integrity c-Class blades, yet they maintain their
compatibility with Proliant c-Class blades.
The new card versions are sold using the same product number as the previous versions; that is,
403621-B21, but with a new Engineering Date Code to identify the new cards as being compatible
with HP Integrity BladeSystems.
It is not possible to update previous recipes/versions of the Mezzanine card to be compatible with
the HP Integrity blades.
Identification
The following are the ways to identify the versions of the cards that are compatible with Integrity
c-Class blades.
EDC change
The newer cards are built with an Engineering Date Code that marks the changes required for
Integrity Integrity-supported versions have an EDC of B-4813 or later.
The EDC code is printed on a label on the box containing the card, on a label on the card, and
is included in the Vital Products Data (VPD) that is flashed into the card during the manufacture of
Compatibility and installation requirements 9