FibrChanl-02 (fclp) B.11.31.1311 Fibre Channel Mass Storage Driver for HP-UX 11i v3 Release Notes
Table 20 Table of Driver Versions (continued)
Release DateDriver VersionRelease Name
March 2013B.11.31.1303Web Release 1303
October 2013B.11.31.1310Web Release 1310
November 2013B.11.31.1311Web Release 1311
Hardware Requirements
This version of the FibrChanl-02 (fclp) Fibre Channel Mass Storage Driver for HP-UX 11i v3 runs
on HP Integrity servers with the HP-UX 11i v3 (11.31) operating system. It supports Fibre Channel
hardware products such as:
• AH403A PCIe Dual Port 8Gb Fibre Channel Adapter
• AH402A PCIe Single Port 8Gb Fibre Channel Adapter
• 456972-B21 Dual Port PCIe Emulex 8 Gb Mezzanine Fibre Channel Adapter
• AD355A PCIe Dual Port 4Gb Fibre Channel Adapter
• AD299A PCIe Single Port 4Gb Fibre Channel Adapter
• AD221A HP PCIe Single Port 4Gb Fibre Channel and Single Port 1000 BT Adapter
• AD222A HP PCIe Dual Port 4Gb Fibre Channel and Dual Port 1000BT Adapter
• AD393A HP PCIe Dual Port 4Gb Fibre Channel and Dual Port 1000SX Adapter
• 403621-B21 Emulex LPe1105–HP 4Gb Fibre Channel Adapter for HP c-Class BladeSystem
• AT094A PCIe Fibre Channel 2-port 8Gb FC/2-port 1/10GBE Combo Adapter
NOTE: Please note these slot limitations on rx3600 and rx6600 servers:
• Slots 5 and 6 are the recommended slots for AD221A, AD222A, and AD393A adapters.
• Slots 3 and 4 are also supported for AD221A, AD222A, and AD393A adapters, but with
these restrictions:
I/O performance of the card may be limited.
Online Replacement is not supported.
Emulex 4Gb Fibre Channel Mezzanine (403621-B21) on HP Integrity blade servers
The Emulex LPe1105-HP 4Gb Fibre Channel Mezzanine Card for HP c-Class BladeSystem (Product
Number 403621-B21) has been shipping on HP Proliant c-Class blades for some time. The cards
have been modified to be compatible with HP Integrity c-Class blades, yet they maintain their
compatibility with Proliant c-Class blades.
The new card versions are sold using the same product number as the previous versions; that is,
403621-B21, but with a new Engineering Date Code to identify the new cards as being compatible
with HP Integrity BladeSystems.
It is not possible to update previous recipes/versions of the Mezzanine card to be compatible with
the HP Integrity blades.
Identification
These are the ways to identify the versions of the cards that are compatible with Integrity c-Class
blades.
12