FibrChanl-02 (fclp) B.11.31.1311 Fibre Channel Mass Storage Driver for HP-UX 11i v3 Release Notes
Table 14 HP-UX September 2009 Fixes
DescriptionDefect ID
There are no fixes in the 0909 release.N/A
Table 15 HP-UX June 2009 Fixes
DescriptionDefect ID
vgchange fails to activate volume groups under the fclp driverQXCR1000886720
Table 16 HP-UX March 2009 Fixes
DescriptionDefect ID
This fix delivers the concurrent dump functionality to the driver.QXCR1000772840
Table 17 HP-UX December 2008 Fixes
DescriptionDefect ID
The fix delivers the SNIA API HBA_GetFcpTargetMappingV2(), which is used to oormation about
the targets mapped through a port on a multiport Fibre Channel card.btain inf
QXCR1000867632
vPars boot panic with AD222 HBA has been fixed.QXCR1000841117
System panic due to spinlock being held too long in a tracing loop has been fixed.QXCR1000869847
The case where the fclp driver did not recognize a device with a loop ID of zero on a private
loop has been fixed.
QXCR1000886304
Table 18 HP-UX September 2008 Fixes
DescriptionDefect ID
Fixed an issue which caused system dump failure to an fclp attached device, if base page size
was set to a value other than 4 KB.
QXCR1000799018
Long hardware path from AD221A (PCIe 1 port 4Gb FC and 1 port GigE HBA) card not
recognized by vparmodify. The workaround for this issue is located at this address:http://
docs.hp.com/en/T1335-90091/ar01s05.html
QXCR1000753480
NOTE: AR0803 (Version B.11.31.0803) was the initial release of FibrChanl-02 (fclp) on HP-UX
11i v3.
Known problems and limitations
This section provides a list of known problems and limitations as known to HP at time of publication.
If workarounds are available, they are included.
• VFC deletion time
While executing “hpvmstop” command the time taken to delete a single Integrity VM VFC or
Flex FC VFC depends on total number of targets mapped to the VFC. Each target node port
deletion takes approximately 2 seconds. The greater the number of targets, the higher the
time taken for total target deletion.
• Incorrect speed display
On a vPars and Integrity VM Guest with NPIV VFCs configured on FC adapters, FC Provider
enumeration of FC ports(NPIV VFC ports) will display “MaxSpeed”, “Speed” values as 0.
NOTE: This issue will be solved in future HP-UX vPars and Integrity VM release. Refer to
http://www.hp.com/go/hpux-hpvm-docs for more detail about the release.
Known problems and limitations 7