HP Fibre Channel Mass Storage Adapters Support Guide FibrChanl-01 (fcd) Driver

See the Support Matrix for the Fibre Channel adapter you are troubleshooting for current system
and adapter firmware requirements and other information. Support Matrixes for HP Fibre Channel
adapters are available at: http://www.hp.com/go/hpux-iocards-docs.
Figure 1 Flowchart 1: Configuration Test
1
HP
adapter
displayed?
Enter the
ioscan command
no
no
4
yes
yes
yes
no
B
A
C
E
H
F
2
Enter the
swlist command
Reinstall
Fibre Channel
software
DONE
Device
displayed?
1
Is the
FC FILESET
displayed?
Go to Flowchart 2
On Flowchart 2
CLAIMED?
Hardware
2
yes
no
Is
System Firm-
ware version
adequate?
yes
Update
Firmware
1
Go to Flowchart 2
G
I
D
no
state =
System
Flowchart 1: Configuration Test Procedures
The sections below provide additional detail on the procedures listed in Flowchart 1.
A. Enter the ioscan command to display information about attached peripherals that are
successfully bound to the system; for example, enter /etc/ioscan-f. For more information,
see the ioscan manpage.
B. HP adapter displayed? The ioscan output displays information about every peripheral adapter
in the system backplane.
C. Hardware state = CLAIMED? The hardware state is operational if “CLAIMED” displays for the
Fibre Channel adapter under the Hardware State heading. If the Fibre Channel adapter is
“CLAIMED”, go to H. If the Fibre Channel adapter is not “CLAIMED”, go to number 2 on
Flowchart 2.
D. Check the Support Matrix for the minimum system firmware version required to support the
Fibre Channel adapter in your system, then confirm which system firmware version you have.
Diagnostic Flowcharts 25