HP PCI Tachyon TL/TS/XL2 Fibre Channel Driver Release Notes, December 2007

HP PCI Tachyon XL2 Fibre Channel Driver Release Notes
Installing the HP PCI Tachyon TL/TS/XL2 Fibre Channel Driver
Chapter 1
9
Installing the HP PCI Tachyon TL/TS/XL2 Fibre Channel Driver
To install the FibrChanl-00 HP PCI Tachyon TL/TS/XL2 Fibre Channel driver on an HP-UX 11i v3 system, complete the
following steps:
Step 1. Log in to the HP-UX 11i v3 system as superuser.
Step 2. Download the HP-UX 11i v3 depot in the /tmp directory on your system.
Step 3. Verify whether the HP-UX 11i v3 depot is downloaded successfully.
To verify whether the HP-UX 11i v3 depot is downloaded successfully, enter the following command at the
HP-UX prompt:
# swlist -d @ /tmp/<11.31_depot>
The following information is displayed:
FibrChanl-00 B.11.31 FibreChannel; HW=A6795A, A5158A
Step 4. To install the HP Tachyon TL/TS/XL2 Fibre Channel driver on the HP-UX 11i v3 system, enter the
following command at the HP-UX prompt:
# swinstall -x autoreboot=true -s /tmp/<11.31_depot> FibrChanl-00
The following message is displayed:
Execution Phase Succeeded