HP-UX and Windows OS Installation Guide for HP PCIe 8Gb and 4Gb 2 Port Fibre Channel Emulex Mezzanine HBA HP Part Number: 5991-8056 Published: May 2009 Edition: 1
© Copyright 2009 Hewlett-Packard Development Company, L.P.© Copyright 2009 Emulex Corporation. Hewlett-Packard Company makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Hewlett-Packard shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material.
Table of Contents About this guide.................................................................................................................7 Intended audience..................................................................................................................................7 Related documentation...........................................................................................................................7 Document conventions and symbols....................................
List of Tables 1 2 3 4 3-1 4 HP Model numbers and Product numbers for the FC Mezzanine Emulex HBA...........................7 Document conventions....................................................................................................................7 Supported Operating Systems........................................................................................................9 Supported Server Platforms.......................................................................................
List of Examples 3-1 3-2 3-3 3-4 3-5 3-6 Example of the “fcmsutil /dev/fclp2” command...........................................................................18 Example of Vital Product Data (VPD) after installation...............................................................19 Example of “ioscan” report of agile (new-style) hardware path after installation (HP-UX 11i v3 only)................................................................................................................................
About this guide This guide provides information about installing, configuring, and troubleshooting the following dual channel host bus adapters. Table 1 HP Model numbers and Product numbers for the FC Mezzanine Emulex HBA HP Model Number HP Product Number Description LPe 1205–HP 456972–B21 PCIe 8Gb 2 Port FC Mezzanine Type I HBA LPe 1105 403621–B21 PCIe 4Gb 2 Port FC Mezzanine Type I HBA Intended audience This guide is intended for technical support personnel.
WARNING! Indicates that failure to follow directions could result in bodily harm or death. CAUTION: data. Indicates that failure to follow directions could result in damage to equipment or IMPORTANT: NOTE: TIP: Provides clarifying information or specific instructions. Provides additional information. Provides helpful hints and shortcuts. Subscribers choice HP strongly recommends that customers sign up online using the Subscriber's choice website: http://www.hp.com/go/e-updates.
• • http://www.hp.com/support/ http://www.docs.hp.com Supported Operating Systems See the following table to determine which operating systems are supported on each FC card. Table 3 Supported Operating Systems Product # Speed and Description HP-UX OVMS Windows Linux 456972–B21 8Gb 2P FC Emulex Mezz HBA 11i v3 0903 Release n/a Smart Setup 6.2 n/a 403621–B21 4Gb 2P FC Emulex Mezz HBA 11i v3 0903 Release 8.3-1H1 Smart Setup 6.
1 Installing the HBA The mezzanine FC HBA card is shipped with the installation instructions. If the installation instruction sheet is unavailable, see the following to obtain a copy. Website Link for Installation Instructions Installation instructions for the mezzanine FC HBA card are available at the following link: http://bizsupport1.austin.hp.com/bc/docs/support/SupportManual/c01070160/c01070160.pdf Further information to complete the installation is available at the following link: http://www.hp.
2 Installing the Windows Smart Component Driver Kit This chapter describes how to locate and download the Windows Smart Component driver kit from the web. This chapter also describes how to install or update your Windows driver.
3 Installing the HP-UX Operating System Components The following sections describe the installation instructions for HP-UX operating systems. Fibre Channel Adapter Installation for HP-UX This section contains installation prerequisites, guidelines, and procedures for the Emulex FC HBA card.
NOTE: Patches are available from the website: http://h20392.www2.hp.com/portal/swdepot/index.do. Installing driver software NOTE: Use the following instructions if the driver is provided on a DVD-ROM. If the driver software is downloaded, follow the instructions provided with that file. The driver software, FibrChanl-02, may be downloaded from the following website: http://h20392.www2.hp.com/portal/swdepot/index.do.
15. Install OnlineDiag, which is available at: http://h20392.www2.hp.com/portal/swdepot/index.do OnlineDiag is also available from the HP Support PLUS CD. Installation instructions are available at: http://docs.hp.com/en/diag/st/st_inst.htm Installing Online Diag Failure to properly complete the steps in this procedure may result in erratic system behavior or system failure and may void the warranty. For assistance with this procedure, contact your local HP Authorized Service Provider.
Example 3-1 Example of the “fcmsutil /dev/fclp2” command # fclputil /dev/fclp2 Vendor ID is Device ID is PCI Sub-system Vendor ID is PCI Sub-system ID is Chip version Firmware Version EFI Version EFI Boot Driver-Firmware Dump Available Driver-Firmware Dump Timestamp Topology Link Speed Local N_Port_id is Previous N_Port_id is N_Port Node World Wide Name N_Port Port World Wide Name Switch Port World Wide Name Switch Node World Wide Name Driver state Hardware Path is Maximum Frame Size Driver Version Mar 16 2
Example 3-2 Example of Vital Product Data (VPD) after installation # fcmsutil /dev/fclp2 vpd V I T A L --------- P R O D U C T ------------- D A T A ------- Product Description : "HP BLc Emulex LPe1205-HP 8Gb FC" Part number : "456973-001" Part Serial number : "MY19114XUZ" Engineering Date Code : "A-4904" Mfd. Date : "4911" Misc. Information : "PW=10W; PCIE X8 GEN 2" ROM Firmware version : "1.10A5 SLI-3 (U3F1.10A5)" EFI version : "UU6.
Once the HP Fibre Channel Mass Storage software and hardware are installed and running, use the following steps to verify connectivity: 1. Check the state of all Fibre Channel hardware and interfaces. Enter the ioscan command and verify the Hardware State and the hw Interface state are CLAIMED. If the Fibre Channel device file has not been created, enter the following commands: # insf -e # ioscan -f 2. Verify that all devices you have attached to the Fibre Channel adapter are listed in the ioscan output.
Adapter This is the hardware path of the Fibre Channel adapter that the Logical Unit Number (LUN) is seen. For multiport adapters, this field describes a specific port on the adapter. Domain Dependent on the Fibre Channel Typically the Domain ID of the topology of the HBA. switch the target device is attached, taken from the most significant byte of the N_Port ID of the target device. Area Depends on the Fibre Channel topology of the HBA. 8 HP-UX uses a Domain ID of 8 to indicate private loops.
Table 3-1 Hardware path field descriptions (continued) Logical Unit Addressing The LUN field of the Logical Unit Number. Volume Set Addressing Bits 0 — 2 of the Logical Unit Number. (Flat Space Addressing) For more information about the fields in the Logical Unit Number, see the SCSI Architechture Model — 3 (SAM-3) standards document.
4 Troubleshooting This chapter contains information to help resolve HBA problems that might occur. The chapter contains the following sections: • • • “Using the Event viewer” (page 23) “Viewing the Event log” (page 23) “Accessing the Windows miniport event log codes” (page 23) Using the Event viewer The miniport drivers verify the condition of the HBA's POST LED states. If there is a failure or a suspected failure, an error log entry is issued to the Windows event log.
Index A audience, 7 Windows server update prerequisites, 13 Windows Smart Component, 13 downloading, 13 D driver kit, 13 drivers installing with Smart Component, 13 lpfc, 13 E Event viewer using, 23 H HP Subscriber's choice website, 8 HP technical support, 8 I installation drivers, 13 installing Windows Smart component, 13 L log codes, miniport driver, 23 lpfc driver installation prerequisites, 13 P prerequisites Windows Smart component, 13 R related documentation, 7 S Smart Component, 13 style con