R211x-HP Flexfabric 11900 EVB Command Reference
9
• The interface-number:channel-id argument specifies an S-channel interface or S-channel aggregate
interface.
• The interface-number:channel-id.vsi-local-id argument specifies a VSI or VSI aggregate interface.
Examples
# Display brief VSI information for Ten-GigabitEthernet 1/0/1.
<Sysname> display evb vsi interface ten-gigabitethernet 1/0/1
Status: A -- Association, P -- Pre-association
VSI VTID Type Instance Status
interface version ID
SCH1/0/1:100.0 NA NA NA P
SCH1/0/1:100.1 NA NA NA A
# Display detailed VSI information for Ten-GigabitEthernet 1/0/1.
<Sysname> display evb vsi verbose interface ten-gigabitethernet 1/0/1
S-Channel1/0/1:100
S-Channel1/0/1:100.0,
VSI local-ID: 0, VSI type ID: NA, VSI type version: NA,
VSI instance ID: NA
VSI manager ID: NA
Current VDP status: Pre-association
Filter type: VID
Filter info:
<100>
S-Channel1/0/1:100.1,
VSI local-ID: 1, VSI type ID: 100, VSI type version: 0,
VSI instance ID: 11:2233:4455:6677:8899:1234:5678:9010
VSI manager ID: NA
Current VDP status: Association
Filter type: MAC/VID
Filter info:
<0011-2233-4455, 1000>
Table 5 Command output
Field Descri
p
tion
VSI interface Name of a VSI.
VTID/VSI type ID
VSI type ID.
NA indicates no ID is specified.
Type version/VSI type
version
VSI type version number.
NA indicates no version is specified.
Instance ID/VSI
instance ID
VSI instance ID.
NA indicates no instance ID is specified.
Status Current status of a VSI.
VSI manager ID
Address of the VSI manager.
NA indicates no VSI manager is specified.