R211x-HP Flexfabric 11900 EVB Command Reference

18
Default
The VDP keepalive exponent is 20.
Views
Layer 2 Ethernet interface view, Layer 2 aggregate interface view
Predefined user roles
network-admin
mdc-admin
Parameters
value: Specifies a VDP keepalive exponent in the range of 14 to 31.
Usage guidelines
The value for VDP keepalive time is expressed by the following equation:
VDP keepalive time (seconds) = 1.5 × [ 2
VDP
keepalive
+ (2 × ECP maximum retransmission time + 1) × 2
ECP
retransmission
] × 10
5
For detailed values, see Table 7.
Table 7 us
es 3 and 16 (the defaults) as the ECP maximum retransmission time and the ECP retransmission
exponent to calculate the VDP keepalive time. These two variables take the larger values proposed by the
station and bridge through EVB TLV. The network environment and configurations on the EVB bridge and
station determine whether the defaults are used or the actual proposed values for the ECP maximum
retransmission time and the ECP retransmission exponent are used.
Table 7 Values for VDP keepalive time
VDP kee
alive ex
onent Calculated value (seconds)
Result value (seconds)
14 4.75136 5
15 4.91520 5
16 5.24288 6
17 5.89824 6
18 7.20896 7
19 9.83040 10
20 15.07328 15
21 25.55904 26
22 46.530056 47
23 88.47360 89
24 172.35968 173
25 340.13184 341
26 675.67616 676
27 1346.7648 1347
28 2688.94208 2689
29 5373.29664 5374
30 10742.00576 10743