R211x-HP Flexfabric 11900 FCoE Command Reference
102
Field Descri
p
tion
State State of the interface: Up or Down.
FCID
After an uplink interface goes up, the FC ID allocated by the core switch is displayed.
A downlink interface does not have an FC ID.
If an NPV switch is connected to two fabrics and its two uplink interfaces are assigned
the same FC ID in a VSAN, one uplink interface can be up, but it cannot work as an
uplink interface. In this case, Unavailable in parentheses is displayed after the FCID
field.
NOTE:
There can be multiple fabrics in an FC SAN. For example, in an FC SAN, if there are two
FCF switches that are not interconnected, each FCF switch forms a fabric.
display npv traffic-map
Use display npv traffic-map to display the traffic mapping information (downlink-to-uplink interface
mappings) of the NPV switch.
Syntax
display npv traffic-map [ vsan vsan-id ] [ interface interface-type interface-number ]
Views
Any view
Predefined user roles
network-admin
network-operator
mdc-admin
mdc-operator
Parameters
vsan vsan-id: Specifies a VSAN by its ID in the range of 1 to 3839. If no VSAN is specified, this
command displays the traffic mapping information of all VSANs.
interface interface-type interface-number: Specifies a downlink interface by its type and number. If no
downlink interface is specified, this command displays the traffic mapping information of all downlink
interfaces.
Usage guidelines
This command is available only when the switch is operating in NPV mode.
Examples
# Display traffic mapping information.
<Sysname> display npv traffic-map
NPV traffic map information of VSAN 1:
Server interface External interface
Vfc1 Vfc4