R211x-HP Flexfabric 11900 FCoE Command Reference

30
mdc-operator
Parameters
vsan vsan-id: Specifies a VSAN by its ID in the range of 1 to 3839. If no VSAN is specified, this
command displays the ESS negotiation results of all VSANs.
Examples
# Display the ESS negotiation result in VSAN 2.
<Sysname> display fc ess vsan 2
ESS info of VSAN 2:
Domain: 210
Directory Server Capability:
Accept large name server objects: Yes
Accept small name server objects: No
Accept large + FC-4 Features name server objects: No
Accept small + FC-4 Features name server objects: No
Support receiving ACCept with 0 length: Yes
Fabric Controller Capability:
Support receiving the SW_RSCN Request: Yes
Fabric Configuration Server Capability:
Support basic configuration services: Yes
Support platform configuration services: No
Support topology discovery configuration services: Yes
Support enhanced configuration services: Yes
Table 12 Command output
Field Descri
p
tion
Domain Domain ID of the switch.
Directory Server Capability List of directory server capabilities.
Accept large name server objects
Indicates whether the switch supports accepting large name server
objects (yes for supported and no for not supported).
A large name server object contains the symbolic name of the
N_Port and the symbolic name of the node in addition to the
information of a small name server object.
Accept small name server objects
Indicates whether the switch supports accepting small name server
objects (yes for supported and no for not supported).
A small name server objects contains only the basic information,
and does not contain the symbolic name of the N_Port, the
symbolic name of the node, or information about supported FC-4
features.
Accept large + FC-4 Features name server
objects
Indicates whether the switch supports accepting large +
FC-4-feature name server objects (yes for supported and no for not
supported).
Accept small + FC-4 Features name server
objects
Indicates whether the switch supports accepting small +
FC-4-feature name server objects (yes for supported and no for not
supported).
Support receiving ACCept with 0 length
Indicates whether the switch supports accepting an ACCEPT reply
whose payload is 0 (yes for supported and no for not supported).