R211x-HP Flexfabric 11900 FCoE Command Reference

35
mdc-admin
mdc-operator
Parameters
vsan vsan-id: Displays the SCR list in the specified VSAN. The vsan-id argument is in the range of 1 to
3839. If no VSAN is specified, this command displays the SCR lists of all VSANs.
count: Displays the number of SCR entries.
Examples
# Display the SCR list.
<Sysname> display fc scr-table
SCR table for VSAN 1:
FCID REGISTERED FOR
0x1b0300 fabric detected rscns
0x010121 nx_port detected rscns
--- Total 2 entries ---
# Display the number of SCR entries.
<Sysname> display fc scr-table vsan 1 count
Total entries: 2
Table 16 Command output
Field Descri
p
tion
SCR table for VSAN SCR list in a specified VSAN.
FCID FC address of the N_Port.
REGISTERED FOR
Type of Registered State Change Notification (RSCN) messages and accept:
fabric detected rscns—Accepts all RSCN messages sent by the switches in the
fabric.
nx_port detected rscns—Accepts all RSCN messages sent by N_Ports.
full detected rscns—Accepts all RSCN messages.
Total entries Number of SCR entries in the VSAN.
display fc timer
Use display fc timer to display fabric timers.
Syntax
display fc timer [ distributed-services | error-detect | resource-allocation ] [ vsan vsan-id ]
Views
Any view
Predefined user roles
network-admin
network-operator
mdc-admin