R211x-HP Flexfabric 11900 FCoE Command Reference

52
port trunk vsan
Use port trunk vsan to assign an interface to the specified VSANs as a trunk port, so that the port allows
the specified VSANs to pass through.
Use undo port trunk vsan to remove an interface from the specified VSANs.
Syntax
port trunk vsan vsan-id-list
undo port trunk vsan vsan-id-list
Default
A VFC interface is not assigned to any VSAN as a trunk port.
Views
VFC interface view
Predefined user roles
network-admin
mdc-admin
Parameters
vsan-id-list: Specifies a list of VSANs, in the format of vsan-id-list = { vsan-id1 [ to vsan-id2 ] }&<1-10>,
where vsan-id is in the range of 1 to 3839 and &<1-10> indicates that you can specify up to 10 vsan-id1
[ to vsan-id2 ] parameters.
Examples
# Assign interface VFC 1 to VSANs 1, 2, 10, and 20 through 100.
<Sysname> system-view
[Sysname] interface vfc 1
[Sysname-Vfc1] port trunk vsan 1 to 2 10 20 to 100
vsan
Use vsan to create a VSAN and enter VSAN view. If the VSAN already exists, you directly enter VSAN
view.
Use undo vsan to delete a VSAN.
Syntax
vsan vsan-id
undo vsan vsan-id
Default
Only the default VSAN (VSAN 1) exists.
Views
System view
Predefined user roles
network-admin