R211x-HP Flexfabric 11900 FCoE Command Reference
55
Exchanges are divided into the following categories:
• Protocol exchange—Created only at the server end based on the protocol number and VSAN ID
and used for monitoring connection setup.
• Link exchange—Created at both ends based on the exchange ID and used for packet exchange.
Examples
# (In standalone mode.) Display the protocol exchange entries.
<Sysname> display fc exchange protocol slot 1
Local_ID:EXID Remote_ID:EXID State Slot Protocol
0x000000:65535 0x000000:65535 LISTEN 1 6
# (In IRF mode.) Display the protocol exchange entries.
<Sysname> display fc exchange protocol chassis 1 slot 2
Local_ID:EXID Remote_ID:EXID State Chassis Slot Protocol
0x000000:65535 0x000000:65535 LISTEN 1 2 13
# (In standalone mode.) Display the link exchange entries.
<Sysname> display fc exchange link slot 2
Local_ID:EXID Remote_ID:EXID State Slot Protocol
0x060501:1024 0x010001:1025 ESTABLISHED 2 8
# (In IRF mode.) Display the link exchange entries.
<Sysname> display fc exchange link chassis 3 slot 5
Local_ID:EXID Remote_ID:EXID State Chassis Slot Protocol
0x060501:1024 0x010001:1025 ESTABLISHED 3 5 11
# Display detailed information about the link exchange entries.
<Sysname> display fc exchange link verbose slot 1
slot: 1
protocol: 8
connection info: Local = 0x090801:1155 , Remote = 0x050001:1089
PCB flags: 0x2
FC Class: FC_CLASS_F
connection state: ESTABLISHED
VSAN ID: 25
Table 17 Command output
Field Descri
p
tion
Local_ID:EXID/Local
FC address and exchange ID of the local end
This field is ignored for a protocol exchange.
Remote_ID:EXID/Remote
FC address and exchange ID of the peer end.
This field is ignored for a protocol exchange.