R211x-HP Flexfabric 11900 FCoE Command Reference
60
Preference: 0
Cost: 0
Interface: InLoop0
State: Active
Age: 0h21m36s
Destination/mask: 0xfffffd/24
Protocol: DIRECT
Preference: 0
Cost: 0
Interface: InLoop0
State: Active
Age: 0h21m36s
Table 19 Command output
Field Descri
p
tion
VSAN VSAN number.
Destination/mask FC address/mask.
Protocol
Protocol type:
• DIRECT—Direct routes.
• STATIC—Static routes.
• FSPF—FSPF routes.
Preference Route preference.
Cost Route cost.
Interface Outgoing interface.
State Route state: Active or Inactive.
Age Lifetime of the route in the routing table, in the format of XXhXXmXXs.
# Display the statistics for all the routes in VSAN 5.
<Sysname> display fc routing-table vsan 5 statistics
Routing Table: VSAN 5
Protocol route active added deleted
DIRECT 4 4 4 0
STATIC 1 1 1 0
FSPF 0 0 0 0
Total 5 5 5 0
Table 20 Command output
Field Descri
p
tion
VSAN VSAN number.
Protocol
Protocol type:
• DIRECT—Direct routes.
• STATIC—Static routes.
• FSPF—FSPF routes.