R211x-HP Flexfabric 11900 FCoE Command Reference

64
network-operator
mdc-admin
mdc-operator
Parameters
vsan vsan-id: Specifies a VSAN by its ID in the range of 1 to 3839. If no VSAN is specified, this
command displays information about all FSPF neighbors.
Usage guidelines
Use this command to display FSPF neighbor information, including the neighbor domain ID, neighbor
interface index, outgoing interface index of the local switch, remaining dead interval of the neighbor,
and neighbor state.
Examples
# Display FSPF neighbor information.
<Sysname> display fspf neighbor
FSPF neighbor information of VSAN 1(01):
Interface NbrDomain IfIndex NbrIfIndex Dead Time State
Vfc1 2 0x68 0x68 00:01:06 Full
Table 23 Command output
Field Descri
p
tion
FSPF neighbor information of
VSAN
FSPF neighbor information for a specified VSAN. The value in parentheses is
the domain ID in decimal of the local switch.
Interface Interface name of the local switch.
NbrDomain Neighbor domain ID in decimal.
IfIndex Outgoing interface index of the local switch.
NbrIfIndex Neighbor interface index.
Dead Time
Remaining dead interval of the neighbor. If no hello packet is received from the
neighbor after this interval, the neighbor state changes to Init.
State
Neighbor state:
Down—The neighbor does not start negotiation.
Init—The neighbor has started negotiation.
DB_Exchange—The neighbor has been discovered.
DB_Wait—The local switch has sent the LSR.
DB_Ack_Wait—The neighbor has sent the LSR.
Full—Synchronization is complete.
display fspf statistics
Use display fspf statistics to display FSPF statistics.
Syntax
display fspf statistics [ vsan vsan-id ]