R211x-HP Flexfabric 11900 FCoE Command Reference

69
undo fspf enable
Default
FSPF is enabled after a VSAN is created.
Views
VSAN view
Predefined user roles
network-admin
mdc-admin
Usage guidelines
FSPF-related functions work in a VSAN only after you enable FSPF for the VSAN.
Examples
# Enable FSPF for VSAN 4.
<Sysname> system-view
[Sysname] vsan 4
[Sysname-vsan4] fspf enable
fspf graceful-restart
Use fspf graceful-restart to enable FSPF GR.
Use undo fspf graceful-restart to disable FSPF GR.
Syntax
fspf graceful-restart
undo fspf graceful-restart
Default
FSPF GR is disabled.
Views
System view
Predefined user roles
network-admin
mdc-admin
Usage guidelines
FSPF Graceful Restart (GR) ensures nonstop forwarding of traffic by backing up FSPF configuration
information during a protocol restart (for example, the FSPF process restart triggered by the process
command) or active/standby switchover.
GR involves the following roles:
GR restarter—GR-capable device where a protocol restart or active/standby switchover occurs
GR helper—The GR restarter's neighboring device that assists in the GR process
Examples
# Enable FSPF GR.