R211x-HP Flexfabric 11900 FCoE Configuration Guide

103
[SwitchA] interface vfc 3
[SwitchA-Vfc3] fc mode np
[SwitchA-Vfc3] quit
# Configure downlink interfaces VFC 1 and VFC 2.
[SwitchA] interface vfc 1
[SwitchA-Vfc1] fc mode f
[SwitchA-Vfc1] quit
[SwitchA] interface vfc 2
[SwitchA-Vfc2] fc mode f
[SwitchA-Vfc2] quit
2. Configure Switch B:
# Configure the switch to operate in advanced mode, save the configuration, and reboot the
switch. (Skip this step if the switch is operating in advanced mode.)
<SwitchB> system-view
[SwitchB] system-working-mode advance
Do you want to change the system working mode? [Y/N]:y
The system working mode is changed, please save the configuration and reboot the
system to make it effective.
# Configure the switch to operate in FCF mode, and create VSAN 1.
<SwitchB> system-view
[SwitchB] fcoe-mode fcf
[SwitchB] vsan 1
[SwitchB-vsan1] quit
# Create interface VFC 3, and configure it to operate in F mode.
[SwitchB] interface vfc 3
[SwitchB-Vfc3] fc mode f
# Bind interface VFC 3 to interface Ten-GigabitEthernet 1/0/3, and assign it to VSAN 1 as a trunk
port.
[SwitchB-Vfc3] bind interface ten-gigabitethernet 1/0/3
[SwitchB-Vfc3] port trunk vsan 1
[SwitchB-Vfc3] quit
# Assign interface Ten-GigabitEthernet 1/0/3 to VLAN 10 as a trunk port.
[SwitchB] interface ten-gigabitethernet 1/0/3
[SwitchB-Ten-GigabitEthernet1/0/3] port link-type trunk
[SwitchB-Ten-GigabitEthernet1/0/3] port trunk permit vlan 10
[SwitchB-Ten-GigabitEthernet1/0/3] quit
# Enable FCoE for VLAN 10 and map VLAN 10 to VSAN 1.
[SwitchB] vlan 10
[SwitchB-vlan10] fcoe enable vsan 1
[SwitchB-vlan10] quit
# Permit the members in the default zone in VSAN 1 to access each other.
[SwitchB] vsan 1
[SwitchB-vsan1] zone default-zone permit
[SwitchB-vsan1] quit