R211x-HP Flexfabric 11900 FCoE Configuration Guide
114
[SwitchC-vsan1] quit
4. On Switch A, use the fcping command to ping Switch C and check whether Switch C is reachable.
[SwitchA] fcping fcid fffc03 vsan 1
FCPING fcid 0xfffc03: 128 data bytes, press CTRL_C to break.
Request time out
Request time out
Request time out
Request time out
Request time out
--- 0xfffc03 fcping statistics ---
5 packet(s) transmitted
0 packet(s) received
100.00% packet loss
The output shows that Switch A cannot reach Switch C.
5. Use the fctracert command to identify the faulty node.
[SwitchA] fctracert fcid fffc03 vsan 1
Route present for: 0xfffc03, press CTRL_C to break
20:00:00:0b:46:00:02:82(0xfffc01)
20:00:00:05:30:00:18:db(0xfffc02)
Fctracert uncompleted: no route to destination port.
The output shows that Switch A can reach Switch B, but Switch B cannot reach Switch C. Therefore,
you can use the display fc routing-table command on Switch B to see whether there is a route to
Switch C.