R211x-HP Flexfabric 11900 FCoE Configuration Guide

54
# Bind interface VFC 1 to interface Ten-GigabitEthernet 1/0/1, and assign it to VSAN 1 as a trunk
port.
[SwitchD-Vfc1] bind interface ten-gigabitethernet 1/0/1
[SwitchD-Vfc1] port trunk vsan 1
[SwitchD-Vfc1] quit
# Assign interface Ten-GigabitEthernet 1/0/1 to VLAN 10 as a trunk port.
[SwitchD] interface ten-gigabitethernet 1/0/1
[SwitchD-Ten-GigabitEthernet1/0/1] port link-type trunk
[SwitchD-Ten-GigabitEthernet1/0/1] port trunk permit vlan 10
[SwitchD-Ten-GigabitEthernet1/0/1] quit
# Create interface VFC 2, and configure it to operate in F mode.
[SwitchD] interface vfc 2
[SwitchD-Vfc2] fc mode f
# Bind interface VFC 2 to interface Ten-GigabitEthernet 1/0/2, and assign it to VSAN 1 as a trunk
port.
[SwitchD-Vfc2] bind interface ten-gigabitethernet 1/0/2
[SwitchD-Vfc2] port trunk vsan 1
[SwitchD-Vfc2] quit
# Assign interface Ten-GigabitEthernet 1/0/2 to VLAN 10 as a trunk port.
[SwitchD] interface ten-gigabitethernet 1/0/2
[SwitchD-Ten-GigabitEthernet1/0/2] port link-type trunk
[SwitchD-Ten-GigabitEthernet1/0/2] port trunk permit vlan 10
[SwitchD-Ten-GigabitEthernet1/0/2] quit
# Enable FCoE for VLAN 10 and map VLAN 10 to VSAN 1.
[SwitchD] vlan 10
[SwitchD-vlan10] fcoe enable vsan 1
[SwitchD-vlan10] quit
# Permit the members in the default zone in VSAN 1 to access each other.
[SwitchD] vsan 1
[SwitchD-vsan1] zone default-zone permit
[SwitchD-vsan1] quit
Verifying the configuration
1. Verify the configuration on Switch A:
# Display the domain information of VSAN 1.
[SwitchA] display fc domain vsan 1
Domain Information of VSAN 1:
Running time information:
State: Stable
Switch WWN: 48:33:43:2d:46:43:1A:1A
Fabric name: 48:33:43:2d:46:43:1B:1B
Priority: 128
Domain ID: 11
Configuration information:
Domain configure: Enabled