R211x-HP Flexfabric 11900 Fundamentals Command Reference

183
flash:/boot02.bin
flash:/system04.bin
flash:/ssh04.bin
# In IRF mode (single-chassis), display ISSU status information on the global active MPU after the issu
load command is completed.
<Sysname> display issu state
ISSU state: Loaded
Compatibility: Compatible
Work state: Normal
Upgrade method: Card by card
Upgraded slot:
chassis 1 slot 5
Current upgrading slot: None
Previous version list:
boot: 7.1.045, Release 2110
system: 7.1.045, Release 2110
ssh: 7.1.045, Release 2110
Previous software images:
flash:/boot.bin
flash:/system.bin
flash:/ssh.bin
Upgrade version list:
system: 7.1.045, Release 2111
ssh: 7.1.045, Release 2111
Upgrade software images:
flash:/system02.bin
flash:/ssh02.bin
# In IRF mode (multichassis), display ISSU status information on the original master after the issu load
command is completed.
<Sysname> display issu state
ISSU state: Loaded
Compatibility: Incompatible
Work state: Independent active
Upgrade method: Chassis by chassis
Upgraded chassis:
chassis 2
Current upgrading chassis: None
Previous version list:
boot: 7.1.045, Release 2110
system: 7.1.045, Release 2110
ssh: 7.1.045, Release 2110
Previous software images:
flash:/boot.bin
flash:/system.bin
flash:/ssh.bin
Upgrade version list:
system: 7.1.045, Release 2111
ssh: 7.1.045, Release 2111