R211x-HP Flexfabric 11900 Fundamentals Command Reference

191
Parameters
boot: Specifies a boot image file. For more information about software images, see Fundamental
Configuration Guide.
system: Specifies a system image file.
feature: Specifies feature image files. &<1-30> indicates that you can specify a space-separated list of
up to 30 feature image files.
patch: Specifies a patch image file.
filename: Specifies the name of a software image file in the root directory of the active MPU's Flash, in
the format flash:/xxx.bin. It can be a case-insensitive string of 1 to 63 characters and cannot contain slot
information. (In standalone mode.)
filename: Specifies the name of a software image file in the root directory of the global active MPU's
Flash, in the format flash:/xxx.bin. It can be a case-insensitive string of 1 to 63 characters and cannot
contain slot or chassis information. (In IRF mode.)
slot slot-number: Specifies a card by its slot number. ( In standalone mode.)
chassis chassis-number slot slot-number: Specifies a card on an IRF member. (In IRF mode.)
test: Only checks for the ISSU method to be used for the upgrade. If you do not specify this keyword, the
command activates the specified software images.
Usage guidelines
An image takes effect only after it is activated.
To keep an activated image active after a reboot, you must confirm the software change by using the
install commit command.
In IRF mode, a subordinate device automatically synchronizes the master device's configuration and
status data at reboot. This process takes time. You must wait for the synchronization to complete before
using the install activate command on the subordinate device. To verify that the synchronization has
completed successfully, do the following:
Use the display device command to verify that all cards of the subordinate device are in normal
state.
Use the display mdc command to verify that all MDCs are in active state.
Use the display system internal ha service-group command to verify that the Action field is 0 for
each service.
Examples
# In standalone mode, check for the ISSU method to be used for feature upgrade of the card in slot 5 with
image file feature1.bin and view the possible impact of the upgrade.
<Sysname> install activate feature flash:/feature1.bin slot 5 test
Upgrade summary according to following table:
flash:/feature1.bin
Running Version New Version
Release 2110 Release 2111
Slot Upgrade Way
5 Service Upgrade