R211x-HP Flexfabric 11900 Fundamentals Command Reference
224
mdc-operator
Parameters
slot slot-number: Specifies a card by its slot number. Without this option, the command displays the
alarm information of all cards. (In standalone mode.)
chassis chassis-number slot slot-number: Specifies a card on an IRF member device by its slot number
and the member ID. Without this option, the command displays the alarm information of all cards in the
IRF fabric. (In IRF mode.)
Examples
# In standalone mode, display alarm information.
<Sysname> display alarm
Slot Level Info
- ERROR Fan 1 is faulty.
- INFO Power 1 is absent.
- INFO Power 2 is absent.
- INFO Power 3 is absent.
Table 27 Command output
Field Descri
p
tion
Slot
Slot number of the card with an alarm. If the value is a hyphen (-), the alarm was
generated by the chassis. (In standalone mode.)
Level
Alarm severity. Possible values include ERROR, WARNING, NOTICE, and INFO, in
descending order.
Info Detailed alarm information.
faulty The card is starting up or is faulty.
# In IRF mode, display alarm information.
<Sysname> display alarm
Chassis Slot Level Info
1 - ERROR Chassis 1 fan 1 is faulty
1 - INFO Chassis 1 power 1 is absent.
1 - INFO Chassis 1 power 2 is absent.
1 - INFO Chassis 1 power 3 is absent.
1 1 ERROR Board is faulty
Table 28 Command output
Field Descri
p
tion
Chassis ID of the IRF member device with an alarm.
Slot Slot number of the card.
Level
Alarm severity. Possible values include ERROR, WARNING, NOTICE, and INFO,
in descending order.
Info Detailed alarm information.
Board is faulty. The card is starting up or is faulty.