R211x-HP Flexfabric 11900 Fundamentals Command Reference
240
Views
Any view
Predefined user roles
network-admin
network-operator
mdc-admin
mdc-operator
Parameters
chassis chassis-number: Specifies an IRF member device by its member ID. (In IRF mode.)
fan-id: Specifies a fan by its ID. The value range for the ID depends on the device model.
Examples
# In standalone mode, display the electronic label information of fan 0.
<Sysname> display device manuinfo fan 0
Fan 0
DEVICE_NAME : HP FlexFabric 11908-V Spare Fan Assembly JG618A
DEVICE_SERIAL_NUMBER : 210212A036X
MAC_ADDRESS : NONE
MANUFACTURING_DATE : 2012-07-05
VENDOR_NAME : HP
# In IRF mode, display the electronic label information of fan 0 on IRF member device 1.
<Sysname> display device manuinfo chassis 1 fan 0
Chassis 1:
Fan 0
DEVICE_NAME : HP FlexFabric 11908-V Spare Fan Assembly JG618A
DEVICE_SERIAL_NUMBER : 210212A036X
MAC_ADDRESS : NONE
MANUFACTURING_DATE : 2012-07-05
VENDOR_NAME : HP
display device manuinfo power
Use display device manuinfo power to display the electronic label information of a power supply.
Syntax
In standalone mode:
display device manuinfo power power-id
In IRF mode:
display device manuinfo chassis chassis-number power power-id
Views
Any view
Predefined user roles
network-admin