R211x-HP Flexfabric 11900 Fundamentals Command Reference

243
slot slot-number: Specifies a card by its slot number.
Usage guidelines
If no card is specified, this command displays the temperature statistics for all temperature sensors
on the device. (In standalone mode.)
If no IRF member device is specified, this command displays the temperature statistics for all
temperature sensors in the IRF fabric. If an IRF member device is specified but you do not specify
any card, this command displays the temperature statistics for all sensors on the specified IRF
member device. (In IRF mode.)
Examples
# In standalone mode, display the temperature statistics for all temperature sensors on the device.
<Sysname> display environment
System temperature information (degree centigrade):
----------------------------------------------------------------------
Slot Sensor Temperature Lower Warning Alarm Shutdown
1 hotspot 1 31 0 48 60 NA
1 hotspot 2 36 0 80 95 110
1 inflow 1 31 0 48 60 NA
1 hotspot 1 36 0 80 95 NA
5 inflow 1 31 0 48 60 NA
5 hotspot 1 36 0 80 95 NA
10 hotspot 1 54 0 68 80 NA
10 hotspot 2 54 0 68 80 NA
10 hotspot 3 54 0 88 100 110
10 hotspot 4 54 0 88 100 110
# In IRF mode, display the temperature statistics for all temperature sensors in the IRF fabric.
<Sysname> display environment
System temperature information (degree centigrade):
----------------------------------------------------------------------
Chassis Slot Sensor Temperature Lower Warning Alarm Shutdown
1 1 hotspot 1 31 0 48 60 NA
1 1 hotspot 2 36 0 80 95 110
1 5 inflow 1 31 0 48 60 NA
1 5 hotspot 1 36 0 80 95 NA
1 10 hotspot 1 54 0 68 80 NA
1 10 hotspot 2 54 0 68 80 NA
1 10 hotspot 3 54 0 88 100 110
1 10 hotspot 4 54 0 88 100 110
Table 32 Command output
Field Descri
p
tion
System temperature
information (degree
centigrade)
Temperature information (°C).
Sensor
Temperature sensor:
hotspot—Hotspot sensor.
inflow—Air inlet sensor.