R211x-HP Flexfabric 11900 Fundamentals Command Reference

256
Table 38 Command output
Field Descri
p
tion
transceiver current alarm information Alarms present on the transceiver module.
RX loss of signal Received signals are lost.
RX power low Received power is low.
display transceiver diagnosis
Use display transceiver diagnosis to display the current values of the digital diagnosis parameters on
transceiver modules.
Syntax
display transceiver diagnosis interface [ interface-type interface-number ]
Views
Any view
Predefined user roles
network-admin
network-operator
mdc-admin
mdc-operator
Parameters
interface [ interface-type interface-number ]: Specifies an interface by its type and number. If no interface
is specified, this command displays the current values of the digital diagnosis parameters on every
transceiver module.
Usage guidelines
This command cannot display information about some transceiver modules.
Examples
# Display the current values of the digital diagnosis parameters on the transceiver module in interface
Ten-GigabitEthernet1/0/1.
<Sysname> display transceiver diagnosis interface ten-gigabitethernet 1/0/1
GigabitEthernet1/0/1 transceiver diagnostic information:
Current diagnostic parameters:
Temp(°C) Voltage(V) Bias(mA) RX power(dBm) TX power(dBm)
36 3.31 6.13 -35.64 -5.19
Table 39 Command output
Field Descri
p
tion
transceiver diagnostic information Digital diagnosis information of the transceiver module in the interface.
Temp.(°C) Temperature in °C, accurate to 1°C.
Voltage(V) Voltage in V, accurate to 0.01 V.