R211x-HP Flexfabric 11900 Fundamentals Command Reference
278
chassis chassis-number: Sets the asset profiles on the specified IRF member device. The chassis-number
argument represents the IRF member ID of the switch. (In IRF mode.)
Usage guidelines
If you execute this command multiple times, the most recent configuration takes effect.
If you specify a fan tray or power supply to set its asset profile, but the specified fan tray or power supply
does not exist, the system prompts that the fan tray or power supply is not present.
Examples
# In standalone mode, set the asset ID of fan tray 0 to 1234 56 .
<Sysname> system-view
[Sysname] set asset-info fan 0 csn 123456
# In IRF mode, set the asset ID of fan tray 0 on IRF member device 1 to 123456 .
<Sysname> system-view
[Sysname] set asset-info chassis 1 fan 0 csn 123456
Related commands
• display asset-info
• reset asset-info
shutdown-interval
Use shutdown-interval to set the detection timer.
Use undo shutdown-interval to restore the default.
Syntax
shutdown-interval time
undo shutdown-interval
Default
The detection interval is 30 seconds.
Views
System view
Predefined user roles
network-admin
mdc-admin
Parameters
time: Specifies a detection timer (in seconds) in the range of 1 to 300.
Usage guidelines
The device starts a detection timer when a port is shut down by a protocol. If the port is still down when
the detection timer expires, the device automatically brings up the port so the port status reflects the port's
actual physical status.
If you change the detection timer to T1 during port detection, the interval from when you change the timer
to the time when the protocol module shuts down the port is T. If T<T1, the down port will be recovered
after T1-T time. If T>=T1, the down port is recovered immediately. For example, if the detection timer is set