R211x-HP Flexfabric 11900 Fundamentals Command Reference
279
to 30 seconds and you change it to 10 seconds (T1=10) two seconds after the port is shut down (T=2),
this port will be recovered 8 seconds later. If the detection timer is set to 30 seconds and you change it
to 2 seconds ten seconds after the port is shut down, this port is recovered immediately.
Examples
# Set the detection timer to 100 seconds.
<Sysname> system-view
[Sysname] shutdown-interval 100
switch-fabric removal-signal-suppression
Use switch-fabric removal-signal-suppression to disable the switching fabric module from sending
removal interrupt signals before it is removed.
Use undo switch-fabric removal-signal-suppression to restore the default.
Syntax
switch-fabric removal-signal-suppression
undo switch-fabric removal-signal-suppression
Default
The switching fabric module sends removal interrupt signals before it is removed.
Views
System view
Predefined user roles
network-admin
mdc-admin
Usage guidelines
If the switching fabric module frequently sends incorrect removal interrupt signals before it is removed, the
device might fail. To avoid this situation, configure the switch-fabric removal-signal-suppression
command.
Examples
# Disable the switching fabric module from sending removal interrupt signals before it is removed.
<Sysname> system-view
[Sysname] switch-fabric removal-signal-suppression
switch-mode
Use switch-mode to set the operating mode of an LPU.
Use undo switch-mode to restore the default.
Syntax
• In standalone mode:
switch-mode { normal | standard-ipv6 } slot slot-number
undo switch-mode slot slot-number
• In IRF mode: