R211x-HP Flexfabric 11900 Fundamentals Command Reference

282
Usage guidelines
The supported features and the specifications of the supported features vary with the operating mode of
the device. For example, the device supports FCoE only when it is operating in advanced mode.
After changing the operating mode, you must reboot the device to make the device operate in the new
mode.
Examples
# Set the operating mode to advanced.
<Sysname> system-view
[Sysname] system-working-mode advance
The system working mode is changed, it will take effect after system restart.
temperature-limit
Use temperature-limit to set the temperature alarm thresholds for the device.
Use undo temperature-limit to restore the default.
Syntax
In standalone mode:
temperature-limit slot slot-number { hotspot | inflow } sensor-number lowlimit warninglimit [ alarmlimit ]
undo temperature-limit slot slot-number { hotspot | inflow } sensor-number
In IRF mode:
temperature-limit chassis chassis-number { slot slot-number } { hotspot | inflow } sensor-number lowlimit
warninglimit [ alarmlimit ]
undo temperature-limit chassis chassis-number { slot slot-number } { hotspot | inflow } sensor-number
Default
Table 43 Default temperature alarm thresholds
Card type Sensor
Low-temperature
threshold
Warning
threshold
Alarming
threshold
Shutdown
threshold
MPU
Inflow 1 0°C (32°F)
48°C
(118.4°F)
60°C
(140°F)
N/A
Hotspot 1
0°C (32°F)
80°C
(176°F)
95°C
(203°F)
N/A
LSU1FAB08D
Hotspot 1
Hotspot 2
0°C (32°F)
68°C
(154.4°F)
80°C
(176°F)
N/A
Hotspot 3
Hotspot 4
0°C (32°F)
88°C
(190.4°F)
100°C
(212°F)
110°C
(230°F)
SF card
LSU1TGS48SF
Hotspot 1
Hotspot 2
0°C (32°F)
68°C
(154.4°F)
80°C
(176°F)
N/A
Hotspot 3
to
Hotspot 5
0°C (32°F)
88°C
(190.4°F)
100°C
(212°F)
110°C
(230°F)