R211x-HP Flexfabric 11900 Fundamentals Command Reference

284
Card type Sensor
Low-temperature
threshold
Warning
threshold
Alarming
threshold
Hotspot 2
–5°C to +5°C
(23°F to 41°F)
78°C to 93°C
(172.4°F to
199.4°F)
90°C to 105°C
(194°F to 221°F)
SF card
LSU1TGS48SF
Hotspot 1
Hotspot 2
–5°C to +5°C
(23°F to 41°F)
58°C to 73°C
(136.4°F to
163.4°F)
70°C to 85°C
(158°F to 185°F)
Hotspot 3
to
Hotspot 5
–5°C to +5°C
(23°F to 41°F)
78°C to 93°C
(172.4°F to
199.4°F)
90°C to 105°C
(194°F to 221°F)
LSU1TGS32SF
LSU1QGS4SF
LSU1QGS8SF
LSU1TGT24SF
Hotspot 1
–5°C to +5°C
(23°F to 41°F)
58°C to 73°C
(136.4°F to
163.4°F)
70°C to 85°C
(158°F to 185°F)
Hotspot 2
–5°C to +5°C
(23°F to 41°F)
78°C to 93°C
(172.4°F to
199.4°F)
90°C to 105°C
(194°F to 221°F)
Usage guidelines
When the device temperature drops below the low-temperature threshold or reaches the
high-temperature warning threshold, the device logs the event and sends a log message and a trap.
When the device temperature reaches the high-temperature alarming threshold, the device logs the event
and notifies users by sending log messages and traps repeatedly and setting the LEDs on the device
panel.
The high-temperature warning threshold must be higher than the low-temperature threshold. The
high-temperature alarming threshold must be higher than the high-temperature warning threshold.
When the temperature of a card reaches the shutdown threshold, the device logs the event, notifies users
by repeatedly sending log messages, and shuts down the card. The shutdown threshold is not
configurable.
Examples
# In standalone mode, set the low-temperature threshold for hotspot sensor 1 on the card in slot 0 to
–10°C (14°F), the warning threshold to 70°C (158°F), and the alarming threshold to 95°C (203°F).
<Sysname> system-view
[sysname] temperature-limit slot 0 hotspot 1 -10 70 95
# In IRF mode, set the low-temperature threshold for hotspot sensor 1 on the card in slot 0 on IRF member
device 1 to –10°C (14°F), the warning threshold to 70°C (158°F), and the alarming threshold to 95°C
(203°F).
<Sysname> system-view
[sysname] temperature-limit chassis 1 slot 0 hotspot 1 -10 70 95
time at
Use time at to specify an execution date and time for a one-time schedule.
Use undo time to remove the execution time configuration for a schedule.