R211x-HP Flexfabric 11900 Fundamentals Configuration Guide
131
flash:/boot-r2110.bin
flash:/system-r2110.bin
flash:/feature1-r2110.bin
# Identify the ISSU method and possible impacts of the upgrade on the device.
<Sysname> display version comp-matrix file feature flash:/feature1-r2111.bin
Feature image: flash:/feature1-r2111.bin
Version:
V700R001B45D002
Version Compatibility List:
V700R001B45D001
V700R001B45D002
Version Dependency System List:
V700R001B45D001
V700R001B45D002
Slot Upgrade Way
4 Service Upgrade
5 Service Upgrade
Influenced service according to following table on slot 4:
flash:/feature1-r2111.bin
feature1
Influenced service according to following table on slot 5:
flash:/feature1-r2111.bin
feature1
The output shows that an incremental upgrade is recommended and the feature1 feature module will be
rebooted during the upgrade process.
# Upgrade feature1 on the standby MPU.
<Sysname> issu load file feature flash:/feature1-r2111.bin slot 5
This operation will delete the rollback point information for the previous upgrade and
maybe get unsaved configuration lost. Continue? [Y/N]:y
Upgrade summary according to following table:
flash:/feature1-r2111.bin
Running Version New Version
Release 2110 Release 2111
Slot Upgrade Way
5 Service Upgrade
Upgrading software images to compatible versions. Continue? [Y/N]: y
# Perform an active/standby switchover.
<Sysname> issu run switchover
Upgrade summary according to following table:
flash:/feature1-r2111.bin
Running Version New Version
Release 2110 Release 2111
Slot Switchover Way
4 Active standby process switchover
Upgrading software images to compatible versions. Continue? [Y/N]: y
# Upgrade the feature on the original active MPU.










