R211x-HP Flexfabric 11900 Fundamentals Configuration Guide

171
Notification Triggering condition Remarks
Severe alarm-removed
notification
The amount of free memory space
increases to or above the minor
alarm threshold.
N/A
Minor alarm-removed
notification
The amount of free memory space
increases to or above the normal
state threshold.
N/A
Figure 48 Memory alarm notification and alarm-removed notification
To set memory usage thresholds:
Step Command Remarks
1. Enter system view.
system-view N/A
2. Set memory usage
thresholds.
In standalone mode:
memory-threshold [ slot slot-number ]
minor minor-value severe severe-value
critical critical-value normal normal-value
In IRF mode:
memory-threshold [ chassis
chassis-number slot slot-number ] minor
minor-value severe severe-value critical
critical-value normal normal-value
The defaults are as follows:
Minor alarm threshold—96 MB.
Severe alarm threshold—64
MB.
Critical alarm threshold—48
MB.
Normal state threshold—128
MB.
Configuring the temperature alarm thresholds
You can set a low-temperature threshold, a high-temperature warning threshold, a high-temperature
alarming threshold, and a high-temperature shutdown threshold to monitor the temperature of the device
through its temperature sensors.
When the temperature drops below the low-temperature threshold or reaches the high-temperature
warning threshold, the device logs the event and sends out a log message and a trap.
When the temperature reaches the high-temperature alarming threshold, the device logs the event and
notifies users by repeatedly sending log messages and traps and by setting the LEDs on the device panel.
Minor
Critical
Free memory space
Severe
Normal
Minor alarm-removed
Severe alarm-removed
Time
Minor
alarm
Severe alarm
Critical alarm
Critical alarm-removed