When the temperature of a card reaches the shutdown threshold, the device logs the event, notifies users
by repeatedly sending log messages, and shuts down the card. The shutdown threshold is not
configurable.
To configure the temperature alarm thresholds:
Ste
p
Command
Remarks
1. Enter system view.
system-view N/A
2. Configure the temperature
alarm thresholds.
• In standalone mode:
temperature-limit slot slot-number
{ hotspot | inflow } sensor-number
lowlimit warninglimit [ alarmlimit ]
• In IRF mode:
temperature-limit chassis
chassis-number { slot slot-number }
{ hotspot | inflow } sensor-number
lowlimit warninglimit [ alarmlimit ]
For the default settings, see Table
16.
The high-temperature alarming
threshold must be higher than the
high-temperature warning
threshold. The high-temperature
warning threshold must be higher
than the low-temperature
threshold.
Table 16 Default temperature alarm thresholds
Card type Sensor
Low-temperature
threshold
Warning
threshold
Alarming
threshold
Shutdown
threshold
MPU
Inflow 1 0°C (32°F)
48°C
(118.4°F)
60°C
(140°F)
N/A
Hotspot 1
0°C (32°F)
80°C
(176°F)
95°C
(203°F)
N/A
LSU1FAB08D
Hotspot 1
Hotspot 2
0°C (32°F)
68°C
(154.4°F)
80°C
(176°F)
N/A
Hotspot 3
Hotspot 4
0°C (32°F)
88°C
(190.4°F)
100°C
(212°F)
110°C
(230°F)
SF card
LSU1TGS48SF
Hotspot 1
Hotspot 2
0°C (32°F)
68°C
(154.4°F)
80°C
(176°F)
N/A
Hotspot 3
to
Hotspot 5
0°C (32°F)
88°C
(190.4°F)
100°C
(212°F)
110°C
(230°F)
LSU1TGS32SF
LSU1QGS4SF
LSU1QGS8SF
LSU1TGT24SF
Hotspot 1
0°C (32°F)
68°C
(154.4°F)
80°C
(176°F)
N/A
Hotspot 2
0°C (32°F)
88°C
(190.4°F)
100°C
(212°F)
110°C
(230°F)
Specifying a traffic load sharing mode for an LPU
The HP 11900 switch series supports load sharing for upstream traffic among LPUs. You can specify
different traffic load sharing modes for different purposes.
Load sharing is available for only unicast traffic.