R211x-HP Flexfabric 11900 High Availability Command Reference

6
OAM timers
Hello timer : 500 milliseconds
Keepalive timer : 5000 milliseconds
Link monitoring
Errored symbol period
Window : 100 x 1000000 symbols
Threshold : 1 error symbols
Errored frame
Window : 10 x 100 milliseconds
Threshold : 1 error frames
Errored frame period
Window : 1000 x 10000 frames
Threshold : 1 error frames
Errored frame seconds
Window : 600 x 100 milliseconds
Threshold : 1 error seconds
Table 3 Command output
Field Descri
p
tion
Global Global information.
Ten-GigabitEthernet1/0/1 Information on Ten-GigabitEthernet 1/0/1.
OAM timers Ethernet OAM connection detection timers.
Hello timer Ethernet OAM handshake packet transmission interval.
Keepalive timer Ethernet OAM connection timeout timer.
Link monitoring Link event detection window and threshold.
Errored symbol period Errored symbol event.
Errored frame Errored frame event.
Errored frame period Errored frame period event.
Errored frame seconds Errored frame seconds event.
Window Detection window configured for link events.
Threshold Triggering threshold configured for link events.
display oam critical-event
Use display oam critical-event to display the statistics on critical Ethernet OAM link events occurred on
a port.
Syntax
display oam critical-event [ interface interface-type interface-number ]
Views
Any view
Predefined user roles
network-admin