R211x-HP Flexfabric 11900 High Availability Command Reference

11
oam errored-frame threshold
Use oam errored-frame threshold to set the errored frame event triggering threshold for a port.
Use undo oam errored-frame threshold to restore the default.
Syntax
oam errored-frame threshold threshold-value
undo oam errored-frame threshold
Default
The port uses the global setting.
Views
Layer 2 Ethernet port view, Layer 3 Ethernet port view
Predefined user roles
network-admin
mdc-admin
Parameters
threshold-value: Specifies the errored frame event triggering threshold in number of errored frame
seconds, in the range of 0 to 4294967295.
Usage guidelines
The configuration in port view takes effect on the specified port. For a port, the configuration in port view
takes precedence.
Examples
# Set the errored frame event triggering threshold to 100.
<Sysname> system-view
[Sysname] interface ten-gigabitethernet 1/0/1
[Sysname-Ten-GigabitEthernet1/0/1] oam errored-frame threshold 100
Related commands
display oam configuration
display oam link-event
oam global errored-frame threshold
oam errored-frame window
Use oam errored-frame window to set the errored frame event detection window.
Use undo oam errored-frame window to restore the default.
Syntax
oam errored-frame window window-value
undo oam errored-frame window
Default