R211x-HP Flexfabric 11900 High Availability Command Reference

15
Use undo oam errored-frame-seconds window to restore the default.
Syntax
oam errored-frame-seconds window window-value
undo oam errored-frame-seconds window
Default
The port uses the global setting.
Views
Layer 2 Ethernet port view, Layer 3 Ethernet port view
Predefined user roles
network-admin
mdc-admin
Parameters
window-value: Specifies the errored frame seconds event detection window in the range of 100 to 9000
and in steps of 10 (in 100 milliseconds).
Usage guidelines
The value of the errored frame seconds event triggering threshold cannot be greater than the value of the
errored frame seconds event detection window (in seconds). Otherwise, errored frame seconds events
cannot be generated.
The configuration in port view takes effect on the specified port. For a port, the configuration in port view
takes precedence.
Examples
# Set the errored frame seconds event detection window to 10000 milliseconds.
<Sysname> system-view
[Sysname] interface ten-gigabitethernet 1/0/1
[Sysname-Ten-GigabitEthernet1/0/1] oam errored-frame-seconds window 100
Related commands
display oam configuration
display oam link-event
oam errored-frame-seconds threshold
oam errored-frame-seconds period
oam errored-symbol-period threshold
Use oam errored-symbol-period threshold to set the errored symbol event triggering threshold.
Use undo oam errored-symbol-period threshold to restore the default.
Syntax
oam errored-symbol-period threshold threshold-value
undo oam errored-symbol-period threshold