R211x-HP Flexfabric 11900 High Availability Command Reference

20
mdc-admin
Parameters
window-value: Specifies the errored frame period event detection window in the range of 1 to 65535.
The value of this argument must be a multiple of 10000.
Usage guidelines
The configuration in system view takes effect on all ports, but has a lower precedence than the
configuration in port view.
Examples
# Set the errored frame period event detection window to 20000000.
<Sysname> system-view
[Sysname] oam global errored-frame-period window 2000
Related commands
display oam configuration
display oam link-event
oam errored-frame-period window
oam global errored-frame-seconds threshold
Use oam global errored-frame-seconds threshold to set the global errored frame seconds event
triggering threshold.
Use undo oam global errored-frame-seconds threshold to restore the default.
Syntax
oam global errored-frame-seconds threshold threshold-value
undo oam global errored-frame-seconds threshold
Default
The global errored frame seconds event detection interval is 1.
Views
System view
Predefined user roles
network-admin
mdc-admin
Parameters
threshold-value: Specifies the errored frame seconds event triggering threshold in the range of 0 to 900.
Usage guidelines
The value of the errored frame seconds event triggering threshold cannot be greater than the value of the
errored frame seconds event detection window (in seconds). Otherwise, errored frame seconds events
cannot be generated.
The configuration in system view takes effect on all ports, but has a lower precedence than the
configuration in port view.