R211x-HP Flexfabric 11900 High Availability Command Reference

26
Related commands
oam enable
oam remote-failure action
Use oam remote-failure action to configure the action the port takes after it receives an Ethernet OAM
event from the remote end.
Use undo oam remote-failure action to restore the default.
Syntax
oam remote-failure { connection-expired | critical-event | dying-gasp | link-fault } action
error-link-down
undo oam remote-failure { connection-expired | critical-event | dying-gasp | link-fault } action
error-link-down
Default
The port only logs the Ethernet OAM event it receives from the remote end.
Views
Layer 2 Ethernet port view, Layer 2 Ethernet port view
Predefined user roles
network-admin
mdc-admin
Parameters
connection-expired: Specifies a connection timeout fault.
critical-event: Specifies a critical fault.
dying-gasp: Specifies a fatal fault.
link-fault: Specifies a link fault.
error-link-down: Terminates the OAM connection, and sets the link state of the port to down.
Examples
# Configure Ten-GigabitEthernet 1/0/1 to terminate the OAM connection after it receives a fatal fault
from the remote end, and set the link state of the port to down.
<Sysname> system-view
[Sysname] interface ten-gigabitethernet 1/0/1
[Sysname-Ten-GigabitEthernet1/0/1] oam remote-failure dying-gasp action error-link-down
oam timer hello
Use oam timer hello to configure the Ethernet OAM handshake packet transmission interval.
Use undo oam timer hello to restore the default.
Syntax
oam timer hello interval
undo oam timer hello