R211x-HP Flexfabric 11900 Layer 2 - LAN Switching Command Reference

128
Table 36 Command output
Field Descri
p
tion
Port Port name.
Receive Number of TC/TCN BPDUs received on each port.
Send Number of TC/TCN BPDUs sent by each port.
instance
Use instance to map a list of VLANs to an MSTI.
Use undo instance to remap the specified VLAN or all VLANs to the CIST (MSTI 0).
Syntax
instance instance-id vlan vlan-id-list
undo instance instance-id [ vlan vlan-id-list ]
Default
All VLANs are mapped to the CIST.
Views
MST region view
Predefined user roles
network-admin
mdc-admin
Parameters
instance-id: Specifies an MSTI ID. The minimum value is 0, representing the CIST, and the maximum
value is 4094.
vlan vlan-id-list: Specifies a VLAN list in the format of vlan-id-list = { vlan-id [ to vlan-id ] }&<1-10>, where
the vlan-id argument represents the VLAN ID in the range of 1 to 4094, and &<1-10> indicates that you
can specify up to 10 VLAN IDs or VLAN ID ranges.
Usage guidelines
If you specify no VLAN in the undo instance command, all VLANs mapped to the specified MSTI are
remapped to the CIST.
You cannot map the same VLAN to different MSTIs. If you map a VLAN that has been mapped to an MSTI
to a new MSTI, the old mapping is automatically removed.
You can configure VLAN-to-instance mapping for up to 65 MSTIs.
After configuring this command, run the active region-configuration command to activate the
VLAN-to-instance mapping.
With digest snooping enabled globally, modify the VLAN-to-instance mappings or execute the undo stp
region-configuration command to restore the default MST region configuration with caution. Such
operations might cause loops or traffic disruption because the VLAN-to-instance mappings are