R211x-HP Flexfabric 11900 Layer 2 - LAN Switching Command Reference
25
mdc-admin
Parameters
delay-time: Sets the physical state change suppression interval (in seconds) on the Ethernet interface. The
value range for this argument is 0 to 30. A value of 0 indicates that physical state changes are
immediately reported to the CPU and are not suppressed.
mode up: Suppresses the link-up events.
mode updown: Suppresses both the link-up and link-down events.
Usage guidelines
When the link-delay delay-time command is configured:
• The link-down event is not reported to the CPU unless the interface is still down when the suppression
interval (delay-time) expires.
• The link-up event is immediately reported.
When the link-delay delay-time mode up command is configured:
• The link-up event is not reported to the CPU unless the interface is still up when the suppression
interval (delay-time) expires.
• The link-down event is immediately reported.
When the link-delay delay-time mode updown command is configured, the link-down or link-up event is
not reported to the CPU unless the interface is still down or up when the suppression interval (delay-time)
expires.
On a port, if you configure the link-delay command multiple times, the most recent configuration takes
effect.
Do not configure this command on a port with MSTP enabled.
Examples
# Set the link-down event suppression interval to 8 seconds on interface Ten-GigabitEthernet 1/0/1.
<Sysname> system-view
[Sysname] interface ten-gigabitethernet 1/0/1
[Sysname-Ten-GigabitEthernet1/0/1] link-delay 8
loopback
Use loopback to perform a loopback test on an Ethernet interface.
Use undo loopback to cancel a loopback test on an Ethernet interface.
Syntax
loopback { external | internal }
undo loopback
Views
Ethernet interface view
Predefined user roles
network-admin