R211x-HP Flexfabric 11900 Network Management and Monitoring Command Reference
121
<Sysname> system-view
[Sysname] snmp-agent sys-info location Room524-row1-3
Related commands
display snmp-agent sys-info
snmp-agent sys-info version
Use snmp-agent sys-info version to enable SNMP versions.
Use undo snmp-agent sys-info version to disable SNMP versions.
Syntax
In non-FIPS mode:
snmp-agent sys-info contact version { all | { v1 | v2c | v3 } * }
undo snmp-agent sys-info version { all | { v1 | v2c | v3 } * }
In FIPS mode:
snmp-agent sys-info version v3
undo snmp-agent sys-info version v3
Default
The default is SNMPv3.
Views
System view
Predefined user roles
network-admin
mdc-admin
Parameters
all: Specifies SNMPv1, SNMPv2c, and SNMPv3.
v1: Specifies SNMPv1.
v2c: Specifies SNMPv2c.
v3: Specifies SNMPv3.
Usage guidelines
SNMPv1 and SNMPv2c settings in this command are supported only in non-FIPS mode.
Configure the SNMP agent with the same SNMP version as the NMS for successful communications
between them.
Examples
# Enable SNMPv3.
<Sysname> system-view
[Sysname] snmp-agent sys-info version v3
Related commands
display snmp-agent sys-info