R211x-HP Flexfabric 11900 Network Management and Monitoring Command Reference
206
[Sysname] nqa entry admin test
[Sysname-nqa-admin-test] type udp-jitter
[Sysname-nqa-admin-test-udp-jitter] reaction 1 checked-element rtt threshold-type
average threshold-value 50 5 action-type trap-only
# Create reaction entry 2 for monitoring the round-trip time of UDP jitter probe packets, setting the upper
limit to 50 milliseconds and lower limit to 5 milliseconds. Before the NQA operation starts, the initial
state of the reaction entry is invalid. After the operation, the packet round-trip time is checked. If the total
number of threshold violations exceeds 100 (included), the state of the entry is set to over-threshold.
Otherwise, the state of the entry is set to below-threshold. Once the state of the reaction entry changes,
a trap message is generated and sent to the NMS.
<Sysname> system-view
[Sysname] nqa entry admin test
[Sysname-nqa-admin-test] type udp-jitter
[Sysname-nqa-admin-test-udp-jitter] reaction 1 checked-element rtt threshold-type
accumulate 100 threshold-value 50 5 action-type trap-only
reaction trap
Use reaction trap to configure the sending of traps to the NMS under specific conditions.
Use undo reaction trap to restore the default.
Syntax
reaction trap { probe-failure consecutive-probe-failures | test-complete | test-failure
cumulate-probe-failures }
undo reaction trap { probe-failure | test-complete | test-failure }
Default
No traps are sent to the NMS.
Views
DHCP operation view, DLSw operation view, DNS operation view, FTP operation view, HTTP operation
view, ICMP echo operation view, SNMP operation view, TCP operation view, UDP echo operation view,
UDP jitter operation view, voice operation view
Predefined user roles
network-admin
mdc-admin
Parameters
probe-failure consecutive-probe-failures: Sends a trap to the NMS if the number of consecutive probe
failures in an operation is greater than or equal to consecutive-probe-failures. The value for
consecutive-probe-failures is in the range of 1 to 15. The system counts the number of consecutive probe
failures for each operation, so multiple traps might be sent.
test-complete: Sends a trap to indicate that the operation is completed.
test-failure cumulate-probe-failures: Sends a trap if the total number of probe failures in an operation is
greater than or equal to cumulate-probe-failures. The value for cumulate-probe-failures is in the range of
1 to 15. The system counts the total probe failures after the last operation completes, so only one trap is
sent.