R211x-HP Flexfabric 11900 Network Management and Monitoring Command Reference
300
• display diagnostic content
diagnostic simulation
Use diagnostic simulation to simulate diagnostic tests.
Use undo diagnostic simulation to restore the default.
Syntax
In standalone mode:
diagnostic simulation slot slot-number-list test test-name { failure | random-failure | success }
undo diagnostic simulation slot slot-number-list test test-name
In IRF mode:
diagnostic simulation chassis chassis-number slot slot-number-list test test-name { failure |
random-failure | success }
undo diagnostic simulation chassis chassis-number slot slot-number-list test test-name
Default
All diagnostic tests are executed instead of simulated.
Views
User view
Predefined user roles
network-admin
Parameters
slot slot-number-list: Specifies a space-separated list of up to 7 slot numbers. Each slot number specifies
a card or a range of cards in the form of slot-number-list = { slot-number [ to slot-number ] }&<1-7>. (In
standalone mode.)
chassis chassis-number: Specifies an IRF member device by its ID. (In IRF mode.)
slot slot-number-list: Specifies a space-separated list of up to 7 slot numbers. Each slot number specifies
a card or a range of cards in the form of slot-number-list = { slot-number [ to slot-number ] }&<1-7>. (In
IRF mode.)
test-name: Specifies a test by its name, a case-insensitive string of 1 to 31 characters.
failure: Configures the system to generate failure results.
random-failure: Configures the system to randomly generate results.
success: Configures the system to generate success results.
Usage guidelines
Test simulation is used to verify GOLD frame functionality. After you execute this command, the system
simulates the specified test if the execution requirements for the test are met. Test simulation does not
trigger hardware correcting actions.
Examples
# (In standalone mode.) Simulate test HGMonitor as failed on card 10.
<sysname> diagnostic simulation slot 10 test HGMonitor failure