R211x-HP Flexfabric 11900 Network Management and Monitoring Command Reference

303
Test interval : 00:00:10
Min interval : 00:00:10
Correct-action : -NA-
Description : A real-time test that checks HG channel status, disabled by default.
Table 67 Command output
Field Descri
p
tion
B/* Boot-up/Not boot-up. The device does not support boot-up diagnostics.
O/* On-demand/Not on-demand. The device does not support on-demand diagnostics.
M/* Monitoring/Not monitoring.
D/* Disruptive/Non-disruptive.
P/* Port-related/Not port-related.
A/I/* Active and monitoring/Inactive and monitoring/Not monitoring.
Test name Name of the diagnostic test.
Test attributes
Attributes of the diagnostic test. The characters from left to right indicate whether or not the
test is boot-up, on-demand, monitoring, disruptive, port-related, and active. The asterisks
(*) represent that the test does not have the corresponding attributes.
Test interval
Execution interval for the test. If the execution interval for the test is not set, –NA–is
displayed.
Min interval
Minimum execution interval for the test. If the test does not have a minimum execution
interval, –NA–is displayed.
Correct-action Correcting action triggered by failure of the test.
Description Description for the test.
display diagnostic event-log
Use display diagnostic event-log to display GOLD log entries.
Syntax
display diagnostic event-log [ error | info ]
Views
Any view
Predefined user roles
network-admin
network-operator
Parameters
error: Displays all error log entries.
info: Displays all log entries except error log entries.
Usage guidelines
If you do not specify the error and info keywords, the command displays all GOLD log entries.