R211x-HP Flexfabric 11900 Network Management and Monitoring Command Reference
306
Field Descri
p
tion
Last failure reason
Cause for the most recent failed test. If the failed test is simulated, Simulated Test is
displayed. If no failure occurs, –NA– is displayed.
Next execution time
Time for the next execution. If the test is a monitoring test, its next execution time is
the most recent execution time plus the execution interval. If the test is not a
monitoring test, –NA– is displayed.
display diagnostic simulation
Use display diagnostic simulation to display configurations for simulated diagnostic tests.
Syntax
In standalone mode:
display diagnostic simulation [ slot slot-number ]
In IRF mode:
display diagnostic simulation [ chassis chassis-number [ slot slot-number ] ]
Views
Any view
Predefined user roles
network-admin
network-operator
Parameters
slot slot-number: Specifies a card by its slot number. If you do not specify this option, configurations for
simulated diagnostic tests on all cards are displayed. (In standalone mode.)
chassis chassis-number [ slot slot-number ]: Specifies a card on an IRF member device. The
chassis-number argument represents the IRF member ID, and the slot-number argument represents the slot
number of the card. If you do not specify an IRF member ID, this command displays configurations for
simulated diagnostic tests on all devices. If no card is specified, this command displays configurations for
simulated diagnostic tests on all cards of the device. (In IRF mode.)
Usage guidelines
This command only displays configurations for simulated diagnostic tests. If no simulated diagnostic test
exists, no information is displayed.
Examples
# (In standalone mode.) Display configurations for all simulated diagnostic tests on card 10.
<sysname> diagnostic simulation slot 10 test HGMonitor failure
<sysname> display diagnostic simulation slot 10
Slot 10:
Name Mode
HGMonitor failure
# (In IRF mode.) Display configurations for all simulated diagnostic tests on card 10 of IRF member device
1.
<sysname> diagnostic simulation chassis 1 slot 10 test HGMonitor failure