R211x-HP Flexfabric 11900 OAA Configuration Guide

2
OAP manager timers
The OAP manager uses two timers:
Clock synchronization timer—Regularly triggers the OAP manager to send clock and time zone
synchronization notifications to OAP clients so the clients' clocks keep synchronized to the
manager's clock.
Client monitoring timer—Regularly triggers the OAP manager to send client monitoring packets to
OAP clients.
Configuring OAP
Enabling OAP
Ste
p
Command
Remarks
1. Enter system view.
system-view N/A
2. Enter interface view.
interface interface-type
interface-number
The interface can be a Layer 2 Ethernet interface, a
Layer 2 aggregate interface, or an Ethernet interface
with the port link-mode route command configured.
For more information, see Layer 2—LAN Switching
Configuration Guide.
3. Enable OAP.
oap enable By default, OAP is disabled on an interface.
Setting the clock synchronization timer
Ste
p
Command
Remarks
1. Enter system view.
system-view N/A
2. Set the clock synchronization
timer.
oap timer clock-sync minutes
By default, the clock
synchronization timer is set to 5
minutes.
Setting the client monitoring timer
Ste
p
Command
Remarks
1. Enter system view.
system-view N/A
2. Set the client monitoring timer.
oap timer monitor seconds
By default, the client monitoring
timer is set to 5 seconds.